Ngokubanzi, iisampulu ezigcinwe yi-nitrogen engamanzi zifuna ixesha elide lokugcina, kwaye zinemfuneko engqongqo kubushushu, obuphakathi kwe-150 ℃ okanye ngaphantsi. Nangona iisampulu ezinjalo zikwafuneka zihlale zisebenza emva kokunyibilika.
Eyona nkxalabo ixhaphakileyo kubasebenzisi kukuba bangazikhusela njani iisampuli ngexesha elide lokugcina, itanki ye-nitrogen yolwelo lwe-aluminium alloy ye-Haier Biomedical inikezela ngezisombululo.
Ithangi leNitrogen yoLwakhiwo lwezonyango lwe-Aluminium Alloy
Ngokungafaniyo nefriji yemveli yoomatshini, itanki ye-nitrogen engamanzi inokugcina iisampuli ngokukhuselekileyo kubushushu obuphantsi kakhulu (-196 ℃) ixesha elide ngaphandle kombane.
Itanki ye-nitrogen engamanzi yezonyango evela kwiHaier Biomedical idibanisa iingenelo zokusetyenziswa kwe-nitrogen engamanzi ephantsi kunye nomthamo ophakathi wokugcina, onokuhlangabezana neemfuno zeengcali kumashishini ahlukeneyo. Le mveliso ifanelekile kumaziko ophando lwezenzululwazi, amashishini e-elektroniki, amakhemikhali, kunye namayeza, kwaye ikwalungele nokugcinwa kweesampuli zeeseli eziqalayo, igazi kunye neentsholongwane kubushushu obuphantsi kwiilebhu, kwizitishi zegazi, kwizibhedlele, nakwamanye amaziko.
Uthotho lweNdawo yokugcina izinto ezincinci
Ubungakanani bemveliso yochungechunge lwezonyango yi-216mm. Kukho iimodeli ezintlanu: 65L, 95L, 115L, 140L kunye ne-175L, ezinokuhlangabezana neemfuno zokugcina zabasebenzisi abahlukeneyo.
Izinga Lokulahleka Komphunga Ophantsi
Ukugqunywa okuphezulu kwe-vacuum kunye nobushushu obuphezulu obunesakhiwo se-aluminiyam esiqinileyo kunokunciphisa kakhulu izinga lokulahleka komphunga we-nitrogen engamanzi, nto leyo egcina iindleko zangaphakathi. Nokuba isampuli igcinwe kwindawo yegesi, ubushushu bungagcinwa buphantsi kune-190 ℃.
Ubuchwepheshe bokugquma ubushushu kunye ne-vacuum
Umatshini wokujija ozenzekelayo ujija ngokulinganayo umaleko wokugquma kunye nobuchwepheshe obuphambili bokugquma ubushushu kunye ne-vacuum ukuqinisekisa ukuba ixesha lokugcina linokufikelela kwiinyanga ezi-4 emva kokongeza i-nitrogen engamanzi.
Ifanelekile Ukugcinwa Kwengxowa Yegazi
Olu luhlu lwezonyango lunokuguqulwa lube zikhongozeli ze-nitrogen engamanzi zokugcina iingxowa zegazi ngokweemfuno zabasebenzisi, ezifanelekileyo ukugcina ubungakanani obuncinci okanye ngaphambi kokuba iingxowa zegazi zidluliselwe kwiitanki ezinkulu ze-nitrogen engamanzi.
Ukubeka esweni ubushushu kunye nendawo yolwelo ngexesha langempela
Akunyanzelekanga ukusebenzisa iHaier Biomedical SmartCap ukujonga ubushushu kunye nenqanaba lolwelo lwetanki ye-nitrogen engamanzi ngexesha langempela, kwaye imeko yokugcina isampuli ingajongwa nangaliphi na ixesha.
Ukhuseleko oluchasene nokuvulwa
Isiciko esiqhelekileyo sokutshixa singaqinisekisa ukuba isampuli ikhuselekile kwaye ayinakuvulwa ngaphandle kwemvume yangaphambili.
Ityala Lomsebenzisi
Ixesha leposi: Februwari-26-2024